Skip to content

MOBILE LIQUID DOSING SYSTEM

Transfer a selected quantity of liquid from an IBC to your process. Enter the dose in kilograms; integrated weighing controls the transfer and stops it at the selected weight loss.

MOBILE LIQUID DOSING SYSTEMLoading 360° view

Drag to rotate

Use left and right arrow keys to rotate; plus and minus to zoom; Home to reset.

Weigh and dose directly from an IBC

The Mobile Liquid Dosing System combines an IBC weighing platform, pneumatic transfer pump, internal valves and local operator controls. Liquid travels directly from the source IBC to a mixer, receiving hopper or separate container. The mobile structure can be repositioned with the IBC installed, subject to the approved operating conditions and handling procedure.

The operator reads the current IBC weight, enters the required dose in kilograms and starts the cycle. The controls operate the pump and internal valves, stopping automatically when the selected quantity has been subtracted from the measured weight. With 155 kg displayed and a 15 kg dose requested, for example, transfer stops at 140 kg.

Pump and transfer rate

Pneumatic pumps are available in ½-inch, 1-inch and 2-inch sizes. Indicative flow rates can reach 10,000 L/h, depending on the pump, liquid viscosity, delivery hose and transfer path. Wolmec sizes the pump for the target dose and available dosing time; the flow rate alone does not define dosing accuracy.

IBC and delivery connections

The support is matched to the IBC dimensions and gross mass. Outlet connections include S60×6, S100×8 or another specified interface, with a rapid coupling to the pump hose. Delivery hose options include 3 m, 5 m and 10 m lengths, selected for the receiving point.

Construction and utilities

Choose AISI 304 or painted carbon steel construction. Ordinary or application-specific ATEX execution is reviewed for the installation. Electrical and compressed-air requirements depend on the selected configuration and must be available at the operating point.

Product change and cleaning

Close the IBC outlet before disconnecting or replacing the container. Cleaning depends on liquid compatibility and permitted carryover. The agreed procedure may use a cleaning liquid or the next product for flushing, with the first transferred quantity discarded where required.

Configure your
system

Choose the starting points for your application. We review your materials, operating conditions and connections before confirming the configuration.

CONFIGURE YOUR APPLICATION

02 INSTALLATION AREA03 LIQUID & SDS04 IBC CONNECTION05 RECEIVING POINT06 DELIVERY HOSE07 UTILITIES08 DOSE & TIME09 CONTACT & SEND
STEP 1 OF 9CONSTRUCTION

STEP 01 / CONSTRUCTION

SELECT THE CONSTRUCTION MATERIAL

Choose the main construction material according to the handled liquid and operating environment.

Product-contact components, seals and pump execution will be selected separately by Wolmec according to the liquid and its Safety Data Sheet.

Practical questions

Before we start

Clear answers to help define the next step.

HOW DOES THE SYSTEM CONTROL THE DOSE?

The weighing platform displays the current weight of the IBC and its contents. The operator enters the quantity to be dosed in kilograms and starts the cycle. The system transfers liquid until that quantity has been subtracted from the displayed weight, then stops automatically. For example: 155 kg displayed, 15 kg requested, automatic stop at 140 kg.

CAN THE SYSTEM BE MOVED WITH THE IBC INSTALLED?

Yes. The mobile structure can be repositioned with the IBC installed, subject to the approved operating conditions and handling procedure.

WHICH IBC SIZES CAN BE USED?

IBC compatibility is checked from the container dimensions, gross mass, outlet connection and approved handling conditions. Wolmec confirms the support and connections after application review.

WHAT FLOW RATE CAN THE SYSTEM ACHIEVE?

Achievable flow is confirmed after reviewing liquid viscosity, pump selection, target dose, available dosing time and transfer route. The pump flow rating alone does not define the performance of the complete dosing system.

HOW IS THE PNEUMATIC PUMP SELECTED?

The pneumatic pump, connections and seals are selected after reviewing the liquid, viscosity, safety data, available compressed air and transfer requirements. Wolmec confirms the final selection for the application.

HOW IS A PRODUCT CHANGE MANAGED?

Isolation, disconnection, replacement and cleaning are defined around the liquids and their compatibility. Residue limits, product-contact materials and the agreed changeover procedure must be reviewed before the system is used with a different product.

IS ATEX EXECUTION ALWAYS REQUIRED?

No. The system is available for ordinary non-explosive environments and can also be configured for ATEX applications when required by the installation area and the liquid handled.

Practical process guides

Prepare your plant project

Start with the information you have. Our team reviews your application and contacts you to define the configuration and quotation.